Laser induced breakdown spectroscopy (LIBS) is basically an emission spectroscopy technique where atoms and ions are primarily formed in their excited states as a result of interaction between a tightly focused laser beam and the material sample. The interaction between matter and high-density photons generates a plasma plume, which evolves with time and may eventually acquire thermodynamic equilibrium. One of the important features of this technique is that it does not require any sample preparation, unlike conventional spectroscopic analytical techniques. Samples in the form of solids, liquids, gels, gases, plasmas and biological materials (like teeth, leaf or blood) can be studied with almost equal ease. LIBS has rapidly developed into a major analytical technology with the capability of detecting all chemical elements in a sample, of real- time response, and of close-contact or stand-off analysis of targets. The present book has been written by active specialists in this field, it includes the basic principles, the latest developments in instrumentation and the applications of LIBS . It will be useful to analytical chemists and spectroscopists as an important source of information and also to graduate students and researchers engaged in the fields of combustion, environmental science, and planetary and space exploration. * Recent research work* Possible future applications* LIBS Principles
Inhaltsverzeichnis
1;Front Cover;1 2;Laser-Induced Breakdown Spectroscopy;4 3;Copyright page;5 4;Table of Contents;6 5;Preface;14 6;Contributors;18 7;Acronyms;22 8;PART I BASIC PHYSICS AND INSTRUMENTATION;26 8.1;Chapter 1. Fundamentals of LIBS;28 8.1.1;1. Introduction;28 8.1.2;2. Lasers for LIBS;29 8.1.2.1;2.1. Mode Properties of Lasers;30 8.1.2.2;2.2. Spatial Intensity Distribution and Focusing of Laser Beam;31 8.1.2.3;2.3. Time Behavior of Laser Pulses;32 8.1.2.4;2.4. Measurement of Laser Power and Energy;33 8.1.2.5;2.5. Varieties of Lasers;34 8.1.3;3. Laser Induced Plasmas;35 8.1.3.1;3.1. Laser Induced Breakdown in Gases;35 8.1.3.2;3.2. Plasma Production from Solid Targets;37 8.1.3.3;3.3. Radiation from Laser Induced Plasmas;39 8.1.4;4. Progress in Detection of LIBS;40 8.1.4.1;4.1. CCD and ICCD Detectors;41 8.1.4.2;4.2. The Spectrograph-Detector Combination;42 8.1.5;5. Applications of LIBS;43 8.1.6;References;44 8.2;Chapter 2. Atomic Emission Spectroscopy;48 8.2.1;1. Introduction;48 8.2.2;2. Measurement of Spectral Lines;49 8.2.3;3. Electronic Structure of Atoms;50 8.2.3.1;3.1. Hydrogenic Atoms;51 8.2.3.2;3.2. Many Electron Atoms;51 8.2.3.3;3.3. Classification of Electronic States;53 8.2.4;4. Radiation From Atoms;54 8.2.4.1;4.1. Electric Dipole Selection Rules;55 8.2.4.2;4.2. Parity Selection Rules;57 8.2.4.3;4.3. Forbidden Transitions;57 8.2.4.4;4.4. Line Strength;58 8.2.4.5;4.5. Oscillator Strength;58 8.2.4.6;4.6. Intensities of Spectral Lines;60 8.2.4.7;4.7. Continuous Emission & Bremsstrahlung;61 8.2.5;5. Broadening of Spectral Lines;62 8.2.5.1;5.1. Stark Broadening;63 8.2.5.2;5.2. Theory of Stark Effect;63 8.2.6;6. Applications;66 8.2.6.1;6.1. Determination of Electron Temperature;66 8.2.6.2;6.2. Determination of the Electron Density;69 8.2.6.3;6.3. Qualitative Emission Analysis;70 8.2.6.4;6.4. Quantitative Emission Analysis;72 8.2.7;References;73 8.3;Chapter 3. Laser Ablation;74 8.3.1;1. Introduction;74 8.3.2;2. Fundamental Ablation Processes;75 8.3.2.1;2.1. Plasma Ignition P
rocesses;77 8.3.2.2;2.2. Plasma Expansion Processes;83 8.3.2.3;2.3. Plasma Emission Spectra;85 8.3.2.4;2.4. Electron Density and Plasma Temperature;87 8.3.3;3. Particle Formation Processes;90 8.3.3.1;3.1. Particle Ejection;90 8.3.3.2;3.2. Nanoparticle Formation;91 8.3.4;4. Laser Ablation Parameters;91 8.3.4.1;4.1. Nanosecond Pulsed Lasers;92 8.3.5;5. Picosecond Pulsed Lasers;98 8.3.6;6. Femtosecond Pulsed Lasers;100 8.3.7;7. Perspectives, Future and Trends;103 8.3.8;References;104 8.4;Chapter 4. Physics of Plasma in LIBS;108 8.4.1;1. Introduction;108 8.4.2;2. Basics of Laser-Matter Interaction;109 8.4.3;3. Processes in Laser Produced Plasma;110 8.4.4;4. Spectral Emission from Plasma;111 8.4.4.1;4.1. Continuum Emission;112 8.4.4.2;4.2. Line Emission;112 8.4.4.3;4.3. Temporal and Spatial Resolution of Emission;112 8.4.5;5. Theoretical Models For Plasma;113 8.4.5.1;5.1. Corona Model;113 8.4.5.2;5.2. Local Thermodynamic Equilibrium Model;114 8.4.5.3;5.3. Collisional Radiative Model;114 8.4.6;6. Measurement of Plasma Parameters;115 8.4.6.1;6.1. Line Broadening;116 8.4.6.2;6.2. Electron Density;117 8.4.6.3;6.3. Plasma Temperature;118 8.4.6.4;6.4. Optical Thickness and Self-absorption;119 8.4.7;7. Characteristics of LIBS Plasma;119 8.4.8;8. Factors Affecting the LIBS Plasma;121 8.4.8.1;8.1. Laser Characteristics;121 8.4.8.2;8.2. Wavelength and Pulse Duration of Laser;123 8.4.8.3;8.3. Properties of Target Material;125 8.4.8.4;8.4. Time Window of Observation;125 8.4.8.5;8.5. Geometric Set-up;127 8.4.8.6;8.6. Ambient Gas;129 8.4.9;9. Methods of Enhancing LIBS Sensitivity;131 8.4.10;10. Conclusion;132 8.4.11;References;133 8.5;Chapter 5. Instrumentation for LIBS;138 8.5.1;1. Introduction;138 8.5.2;2. Typical LIBS Set-up;139 8.5.3;3. LIBS Instrumentation;141 8.5.3.1;3.1. Echelle Spectrometer;143 8.5.3.2;3.2. Specialty of Echelle Spectrometer;144 8.5.4;4. Fiber Optic LIBS;146 8.5.4.1;4.1. Fiber Optic LIBS Probe;146 8.5.4.2;4.2. Transmission Property of Optical Fiber;148 8.5.5;5.
Portable LIBS Devices;148 8.5.6;6. Sensitive LIBS Techniques;150 8.5.7;7. Variety of LIBS Instrumentation;152 8.5.7.1;7.1. Environmental Monitoring;152 8.5.7.2;7.2. LIBS in Space Research;153 8.5.7.3;7.3. LIBS in Industry;154 8.5.8;8. LIBS Experiments & Analytical Performance;154 8.5.9;9. Conclusion;156 8.5.10;References;156 9;PART II NEW LIBS TECHNIQUES;160 9.1;Chapter 6. Dual-Pulse LIBS;162 9.1.1;1. Introduction;162 9.1.2;2. Dual-Pulse LIBS;163 9.1.3;3. Dual-Pulse LIBS Applications;165 9.1.4;4. Dual-Pulse LIBS Mechanistic Studies;168 9.1.5;5. Future Directions;172 9.1.6;References;173 9.2;Chapter 7. Femtosecond LIBS;176 9.2.1;1. Chapter Organization;176 9.2.2;2. Introduction;176 9.2.3;3. Plasma Produced by Ultra-Short Laser Pulses;178 9.2.3.1;3.1. Basic Processes during Laser Ablation;179 9.2.3.2;3.2. Material Removal and Plasma Expansion;180 9.2.3.3;3.3. Influence of the Pulse duration on the Plasma Properties;183 9.2.4;4. Spectrochemical Analysis by Ultra-Short Laser-Induced Plasma;189 9.2.5;5. Non-Gated Analysis by Ultra-Short Laser Pulses;191 9.2.6;6. Conclusions;193 9.2.7;References;194 9.3;Chapter 8. Micro-LIBS;198 9.3.1;1. Introduction;198 9.3.2;2. Microjoule Laser Sources;200 9.3.2.1;2.1. Microchip Lasers;200 9.3.2.2;2.2. Microjoule Fiber Lasers;202 9.3.3;3. Scaling LIBS to Microjoule Energies;203 9.3.3.1;3.1. Plasma Emission and Lifetime;204 9.3.3.2;3.2. Crater Size Lateral and Depth Resolution;206 9.3.3.3;3.3. Limits of Detection;209 9.3.3.4;3.4. Signal Linearity with Concentration;211 9.3.4;4. Applications;211 9.3.4.1;4.1. Microanalysis of Small Volumes;212 9.3.4.2;4.2. Scanning Microanalysis of Material Surfaces;213 9.3.4.3;4.3. Liquid Samples;218 9.3.5;5. Conclusions;218 9.3.6;References;219 10;Part III LIBS APPLICATIONS;222 10.1;Chapter 9. LIBS Application to Off-Gas Measurement;224 10.1.1;1. Introduction;224 10.1.2;2. Experimental Setup;225 10.1.3;3. Calibration;226 10.1.4;4. Applications;231 10.1.4.1;4.1. Analysis of Air-Sampling Filters with LIBS
;231 10.1.4.2;4.2. Continuous Emission Monitor;234 10.1.4.3;4.3. Process Control;238 10.1.4.4;4.4. Filter Efficiency;239 10.1.4.5;4.5. Combustion Diagnostic;241 10.1.4.6;4.6. Rocket Engine Health Monitor;241 10.1.5;5. Conclusion;245 10.1.6;References;245 10.2;Chapter 10. LIBS of Liquid Samples;248 10.2.1;1. Introduction;248 10.2.2;2. LIBS of Liquid Samples;249 10.2.2.1;2.1. Elemental Analysis in Liquids;249 10.2.2.2;2.2. LIBS of Molten Metal;251 10.2.3;3. Instrumentation for Liquid Samples;252 10.2.3.1;3.1. Experimental Setup for Surface Excitation;252 10.2.3.2;3.2. Experimental Set up for Bulk/Molten Liquid;253 10.2.3.3;3.3. Liquid Configuration for Plasma Formation;254 10.2.3.4;3.4. Optimization of Experimental Parameters;255 10.2.4;4. Enhancement in the Sensitivity of LIBS;257 10.2.4.1;4.1. Effects of a Magnetic Field on Plasma;257 10.2.4.2;4.2. Effects of Double Laser Pulse Excitation on LIBS Signal;266 10.2.5;5. Conclusion;277 10.2.6;References;277 10.3;Chapter 11. LIBS of Solid and Molten Material;280 10.3.1;1. Introduction;280 10.3.2;2. FO LIBS Sensor for Determination of Elemental Composition of Solid Aluminum Alloys;281 10.3.2.1;2.1. Parametric Studies;282 10.3.2.2;2.2. Effect of Angle of Incidence on LIBS Signal;286 10.3.2.3;2.3. Calibration Curve;287 10.3.2.4;2.4. Effect of Sample-Lens Distance and Focal Length;294 10.3.3;3. LIBS Spectra of Molten Aluminum Alloy in a Laboratory Furnace;296 10.3.3.1;3.1. Effect of the Surrounding Atmosphere on LIBS Signal;298 10.3.3.2;3.2. Calibration Curves for Molten Aluminum Alloy;300 10.3.3.3;3.3. Comparison of LIBS Spectra of Molten and Solid Alloy Samples;302 10.3.4;4. FO-LIBS Probe for Aluminum Alloy in Industrial Pilot Furnace;305 10.3.4.1;4.1. Testing the Long Stainless Steel Probe;307 10.3.4.2;4.2. LIBS Measurements inside the Industrial Pilot Furnace;307 10.3.5;5. Conclusions;309 10.3.6;References;309 10.4;Chapter 12. LIBS Technique for Powder Materials;312 10.4.1;1. Introduction;312 10.4.2;2. LIBS Technique for
Powder Materials;313 10.4.2.1;2.1. Preparation of the Pellets of the Powder Samples;314 10.4.2.2;2.2. Apparatus;316 10.4.2.3;2.3. Position of the Focal Spot;317 10.4.2.4;2.4. Delay Time;318 10.4.2.5;2.5. Sample Rotating Speed;318 10.4.3;3. Application to Pharmaceutical Industry;319 10.4.3.1;3.1. Introduction;319 10.4.3.2;3.2. Analysis of Organic Materials;320 10.4.3.3;3.3. Experimental Approaches;322 10.4.3.4;3.4. Main Applications;324 10.4.4;4. Prospects: LIBS as a Process Analytical Technology;329 10.4.5;5. Application to Glass Industry;329 10.4.6;References;335 10.5;Chapter 13. LIBS for the Analysis of Chemical and Biological Hazards;338 10.5.1;1. Introduction;338 10.5.2;2. Application to Chemical Hazard Analysis;339 10.5.3;3. Application to Bio-Aerosol & Bio-Agent Detection;340 10.5.3.1;3.1. Deposited or Pelletized Samples;341 10.5.3.2;3.2. Airborne samples;345 10.5.4;4. Conclusion;348 10.5.5;References;348 10.6;Chapter 14. Life Science Applications of LIBS;350 10.6.1;1. Introduction;350 10.6.2;2. Bone & Tooth Analysis;351 10.6.3;3. Hair & Nail Analysis;354 10.6.4;4. Blood Analysis;355 10.6.5;5. Urine Stones Analysis;356 10.6.6;6. Tissue Analysis;357 10.6.7;7. Conclusions;362 10.6.8;References;363 10.7;Chapter 15. Measurement of Carbon for Carbon Sequestration and Site Monitoring;366 10.7.1;1. Introduction;366 10.7.2;2. LIBS Measurements in Soil;367 10.7.3;3. Carbon-Nitrogen Analysis by Sample Combustion;369 10.7.4;4. Acid Washing of Soils to Remove Inorganic Carbon;369 10.7.5;5. Field Measurements;374 10.7.6;6. Conclusions;374 10.7.7;References;375 10.8;Chapter 16. Remote Analysis by LIBS: Application to Space Exploration;378 10.8.1;1. Introduction;378 10.8.2;2. Conventional Stand-off LIBS;379 10.8.2.1;2.1. Apparatus;380 10.8.2.2;2.2. Results;381 10.8.3;3. Stand-off LIBS Using Femtosecond Pulses;383 10.8.3.1;3.1. Femtosecond Laser Pulses and LIBS;383 10.8.3.2;3.2. Remote Sensing using fs Pulse Produced Filamentation;384 10.8.3.3;3.3. Teramobile;386 10.8.3.4;3.
4. Remote LIBS using fs Pulses;386 10.8.4;4. Stand-off LIBS for Space Exploration;387 10.8.4.1;4.1. Spectroscopic Methods of Planetary Analysis;388 10.8.4.2;4.2. Prior Elemental Analysis Methods used on Landers/Rovers;388 10.8.4.3;4.3. Advantages;390 10.8.4.4;4.4. LIBS Characteristics for Stand-off Analysis;393 10.8.4.5;4.5. Capabilities;397 10.8.4.6;4.6. Instrumentation;401 10.8.5;References;403 10.9;Chapter 17. LIBS for Aerosol Analysis;406 10.9.1;1. Introduction;406 10.9.2;2. Fundamentals of Aerosol Analysis;406 10.9.3;3. Laser Induced Breakdown of Gases;408 10.9.4;4. Analysis of Aerosol Particles by LIBS;411 10.9.4.1;4.1. Spectral Ensemble-Averaging;412 10.9.4.2;4.2. Statistical Aerosol Sampling with LIBS;418 10.9.4.3;4.3. Conditional Analysis for Spectral Processing;421 10.9.4.4;4.4. Analysis of Individual Aerosol Particles;427 10.9.5;5. Alternative Methodologies for Aerosol Analysis;429 10.9.6;6. Applications of LIBS-Based Aerosol Analysis;430 10.9.7;7. Future Directions;435 10.9.8;References;438 10.10;Chapter 18. Scope of Future Development in LIBS;444 10.10.1;1. Introduction;444 10.10.2;2. Gas Phase LIBS;444 10.10.3;3. Liquid Phase LIBS;445 10.10.4;4. Solid Phase LIBS;445 10.10.5;5. LIBS of Molten Samples;446 10.10.6;6. Theoretical Models of Laser Induced Plasma;446 10.10.7;7. Commercialization of LIBS;447 10.10.8;8. Future Applications;447 10.10.9;References;449 11;Subject Index;452